arrow-bordered-inner arrow-bordered arrow-slider arrow brochure calendar clock close cubic-box flag left-arrow link pin plus right-arrow social-facebook social-instagram social-linkedin social-rss social-twitter social-vimeo social-youtube

TESTING RESULTS


Environmental test results are for PolyStrata technology only

Moisture Sensitivity PASS - IPC / J-STD-020E, MSL1, 168Hrs., 85C/85RH, 3x solder reflow
Humidity Accelerated Life Test (unbiased) PASS – JESD22-A118B, 130°C, 85% RH, 96 Hrs.
Temperature Cycling/Shock PASS - JESD22-A104E, Cond. B, -55°C to 125°C, 700 cycles
Mechanical Shock PASS - JESD22-B104C, Cond. B, 1500g, 0.5 ms, 6 orientations, 5 shocks/orientation, 30 shocks total
Vibration, Variable Freq. PASS - JESD22-B103B.01, Cond. 1, 20 G, 20 - 2000 Hz, 4 sweeps/axis, 4 min./sweep
Wire Bondable Yes, up to 6hrs @ 150C or 12mins @ 260C (air), Argon Plasma clean, prior to bonding.
Recommended Storage Conditions Prior to wire bonding + lid seal Storage in Nitrogen Environment. Similar to IMS board storage

For reference purposes only